^B29 Enter Pass-Through Mode
Allows direct communication with the PBX. In Pass-Through Mode, data can be received
directly from the PBX in order to check for correct reception. Commands can also be sent
directly to the PBX. While Pass-Through Mode is active, additional call records will not be
stored.
If you are communicating with the PollCat III via the Modem Port, the Pass-Through Mode
also permits direct communication with the device connected to the Computer Port. If
necessary, this allows the user to access a connected device (such as your PBX maintenance
port) via modem.
The Pass-Through Mode features 4 Kbyte buffering in both directions to prevent overflow
problems. Command ^B29 offers the following options:
·
PBX Port A: To access the PBX connected to PBX Port A, type ^B29,A [Enter]. The
system will display the "PBX-A READY" message.
·
PBX Port B: To access the PBX connected to PBX Port B, type ^B29,B [Enter]. The
system will display the "PBX-B READY" message.
·
Computer Port: If you are communicating with the unit via the Modem Port, you can also
access the device connected to the Computer Port. Type ^B29,C [Enter], the system will
return the "READY" message.
Note: To leave the Pass-Through Mode and return to the Command Mode, type
^B30 [Enter].
CAUTION: Please refer to the PBX User's Manual for further instructions. Do
not attempt to alter the configuration or access codes of the PBX unless you are
authorized to do so.
^ B30 Exit to Command Mode
Exits from Data Release Mode, Send Continuous Test Message Mode, Echo Test Mode, Pass-
Through Mode, or Monitor Mode and returns to Command Mode. Type ^B30 [Enter].
^ B37 Load and Test Memory
Tests internal memory. When Command ^B37 is invoked, PollCat III will clear all internal
RAM memory, and load a test pattern, which is then used to verify memory condition.
CAUTION: When Command ^B37 is invoked, all data stored in PollCat III's
internal memory will be lost.
The test will require seven seconds for every 256K of memory. If no problems are detected ,
the "COMPLETE" message will be sent. If a memory error is detected, PollCat III will send a
message similar to the example below:
ERROR: --> SOCKET: 1MB, CHIP: M1
If the test indicates a memory error, please contact WTI Customer Service as shown in
Appendix H. To begin the memory test, type ^B37 [Enter].