3. Hardware Installation
This section describes the hardware installation procedure, which consists of the steps listed
below. For more information, please refer to the corresponding section for each step.
1. Use the Set-Up Switches to select default communication parameters and PollCat III
options.
2. Connect the Data Cables and telephone line.
3. Connect the AC Power Cable to the PollCat III unit.
3.1. Set-Up Switches
The Set-Up Switches are used to select default communication parameters and enable options
such as the Direct Connect Mode, Computer Port Password, and Power Up Default.
3.1.1. Default Baud Rate for Computer Port (Sw1, Sw2, Sw3)
Set-Up Switches One, Two, and Three select the default Baud Rate for the Computer Port.
After the PollCat III is installed, Command ^B91 can also be used to redefine the Computer
Port Baud Rate.
Baud Switch 1 Switch 2 Switch 3
9600 * Down Down Down
38.4 K Up Down Down
19.2 K Down Up Down
4800 Up Up Down
2400 Down Down Up
1200 Up Down Up
600 Down Up Up
300 Up Up Up
* = Factory Setting
3-1