TELCOM RESEARCH TR-2100 DATA BUFFER
By using groups of computer-to-computer commands the TR-2100 will perform all of the
functions necessary for automatic data collection. These commands provide the
functionality listed below.
Communications Commands
• Send the current record to the downstream processing system.
• Advance to the next record.
• Clear all of the previously transmitted records. This command makes room for
new records.
• Reset to the beginning of the buffer. This command helps recover records lost
due to downstream processing failures.
• Doorbell. This command returns a simple ‘Hello’ response to ensure that a
connection to the TR-2100 has been made.
• Maintenance/Support Commands.
• Pass data from the DATA PORT to the CONTROL port for dynamic monitoring of
PBX activity. Data is still processed and retained by the TR-2100.
• Commands to reset the entire TR-2100, or the TR-2100 buffer memory.
• It supports the test and diagnostic Internet Protocols PING, ECHO and
CHARGEN.
Internet Protocol Features
• FTP Protocol used for uploading data to an FTP server.
• HTTP Protocol used for configuration through a WEB Browser.
• Telnet Protocol user for configuration.
• Telnet Protocol for data record retrieval.
• NetBIOS Name Resolution Protocol.
• DHCP Configuration.
• RARP, Reverse Address Resolution Protocol.
• Ethernet Statistics are collected and available.
• Serial Port and Buffer Status Statistics are collected and available.
• PING, ECHO and CHARGEN protocols for network testing and diagnostics.
Buffer Configuration Options
There are several methods of configuring the TR-2100. They are all described in the
following chapters.
TR-2100 Windows Configuration Program
The quickest and easiest method, if there is direct physical access to the TR-2100’s
serial port, is the Telcom Research TR-2100 Windows Configuration Program. A
free download of the latest version can be uploaded from our WEB Site
www.databuffers.com. This program is described starting on page 15.
4